Slink-e / CDJ Discussion Archive #11 Re: New CDJ VersionPosted By: Colby Boles <cboles@n...> In Response To: Re: New CDJ Version (Don Schryver)
Your problem is definitely different. The reason the control line is dropping is that the Slink-e is rebooting, which resets the digital I/O. The question is WHY is your slink-e rebooting? The only reason this should happen is if: 1. it is told to reboot (perhaps a unlucky desynchronized byte sequence sent to the slink-e) 2. it gets sent some other bad byte sequence which leaves it waiting for more bytes and in the meantime the watchdog timer reboots it. 3. some other event causes the slink-e to somehow freeze and causes a watchdog reboot. Colby Responses To This Message