Re: DXS slink control?

Posted By: Colby Boles <cboles@n...>
Date: 12/22/99 12:20pm

In Response To: DXS slink control? (Brooks Talley)

to make output 2 be auto-sensing, issue the following command

dxs:set_outmode[0101]

the first byte of data (01 hex) selects output 2 (numbers are 0-based in this case)

the second byte chooses auto sensing to be on. If you look at the dxsls file, there are comments in it describing the commands and their parameters.

Colby