| Read Responses | Return to Index | Read Prev Msg | Read Next Msg |

Slink-e / CDJ Discussion Archive #3

Re: Paralell port on slinke2

Posted By: Colby Boles <cboles@n...>
Date: 1/25/1999 9:34p.m.

In Response To: Re: Paralell port on slinke2 (Richard Malcolm-Smith)

>>

Slinkx1.Send('low', 'pardir[ff]') ; //All inputs..
<<

Here's the problem. The number in brackets is supposed to be a decimal number. It says so in the documentation, but I apologize for the difference between the lowlevel and the S-Link commands (which are hex). What you need to say is:

'pardir[255]'

I did this for the convenience of VB programmers so that they wouldn't have to hex format their numbers before passing them to SlinkX.

Colby

Responses To This Message

| Read Responses | Return to Index | Read Prev Msg | Read Next Msg |

Password:

Slink-e / CDJ Discussion Archive #3 is maintained by slinke-bbs-owner@nirvis.com with WebBBS 3.21.